I got frustrated as to where is the cause of power problem. Everytime when i switch on the power supply the fuse blowimmediately the fuse became dark color and this indicatethat there is a major short circuit in the power supply. I have checked all the components in the power supply and can't find the culprit!What i do is i desoldered all the suspected parts one by one and replaced with a known good component. I eventually found the caused of the power supplyproblem.

Voltage controlled oscillators are commonly abbreviated as VCO. A VCO is an oscillator whose output frequency is proportional to the applied input voltage. The parts of a VCO circuit has a LC tank circuit with an inductorL and a capacitorC along with one or two transistors accompanied by a buffer amplifier. A VCO gives a periodic output signal where the output signal parameter is directly related to level of input control voltage.

Van de Graaf generators generate static electricity, not very useful, but Tesla coils were originally developed for the wireless transmission of electricity. All you need is two Tesla coils one to transmit and one to receive the energy. I remember reading a story of a lab that had two Tesla coils across the room from each other and they were energizing one and the other had its terminals bonded. After energizing the one they noticed the other started to smoke and they realized that they were transmitting power wirelessly.

In the market there is quite a number of ranges that you can buy. It has the range of 50v, 100v, 250v,500v, 1000v and even 5000v!If you want to test a capacitorof 100 microfarad 160v then you have to select 100v. If youselect 250v, it will blow your capacitor that is under test. If you have the SENCORE TEST EQUIPMENT such as thesencore lc meter LC102 OR LC103, these meters have the capabilities of checking any type of capacitors with four test; testing for capacitor values checking for leakage equivalent series resistance ESR and Dielectric absorptionIt can check aluminum electrolytic capacitor, film capacitor,ceramic, high voltage capacitor and etc. Conclusion Different capacitor manufacturer produced different typeof quality of a capacitor. Perhaps the bad capacitor that iencountered are from the lowest grade one.

The tuning range of the VCO refers to the range of oscillation frequencies attained by varying the varactors. Two important parameters in VCO design are sweep range and linearity. Linearity correlates the change in frequency or the VCO output to the change in the control voltage. The sweep range is the range of possible frequencies produced by VCO control voltage. Voltage controlled oscillators are basic building blocks of many electronic systems especially phase locked loopsPLL and may be found in computer disk drives, wireless electronic equipment such as cellular telephones, and other systems in which oscillation frequency is controlled by an applied tuning voltage.

I believed most of you know how to check capacitors and also generally using this type of meters. Measured with analog it showed capacitor charging and discharge, with digitalcapacitor tester it showed around 220 microfarad and withesr meter it showed low esr reading!This proved that the bad capacitor breakdown when underfull operating voltage. Then, how do i confirm that thisfilter capacitor is faulty?By using an analog insulation tester. When i connect the faulty cap to the meter and pressthe go button it showed a very low resistance and this is the proved of short circuit between the plate when voltage applied!There is nothing to do with bad electrolyte. A good capacitor will just showed a charge and discharge in theinsulation meter just like you are checking a capacitor usinganalog multimeter.

Guess what?It was the main filter capacitor220 microfarad 400 volt. After replacing the filter capthe power supply worked perfectly fine. I begin my detective work to find out why this capacitor can caused the fuse to blow eventhough i already confirmed it ok with my meters. The meters that i used to check the filter cap were analogmeter, digital capacitance meter and esr meter. In thisarticle i will not explain about how to check capacitor ortesting capacitor and how capacitor work.

The researchers explain that stretchable supercapacitors can power some future devices themselves, or can be combined with other components to overcome engineering challenges. For example, supercapacitors can be charged in seconds and then slowly charge the battery, which is the main source of energy for the device. This method has been used for regenerative braking of hybrid vehicles, in which energy is generated faster than stored. Super capacitors increase the efficiency of the entire system.